Skip to main content

Water Service ELITE

Maintenance Best Practices

Essential guidelines for routine inspections, filter replacements, and system flushing to keep your water treatment system in top condition

Advanced Ultra-Filtration

Industrial water filtration system with two tall grey tanks, a black top component, blue accents, and a control panel on the right
UF-7.5 Single

1 Ultra Filtration Membrane + 1 Cartridge With a 7.5 GPM Flow Rate

Industrial water filtration system with two black pressure vessels and a control panel.
UF-15 Double Double

2 Ultra Filtration Membrane + 2 Cartridge With a 15 GPM Flow Rate

Industrial water filtration system with vertical tanks, gauges, and a control panel on a metal frame.
UF-15 Double

1 Ultra Filtration Membrane + 2 Cartridge With a 15 GPM Flow Rate

Industrial water filtration system with multiple tall gray tanks, blue caps, and monitoring panel
UF-30 Quad

2 Ultra Filtration Membrane + 4 Cartridge With a 30 GPM Flow Rate

Industrial water treatment skid with twin filtration modules and blue-capped tanks, featuring gauges and control panels on each side.
UF-60 Octuple

4 Ultra Filtration Membrane + 8 Cartridge With a 60 GPM Flow Rate

UF-7.5 Single

1 Ultra Filtration Membrane + 1 Cartridge With a 7.5 GPM Flow Rate

UF-15 Double Double

2 Ultra Filtration Membranes + 2 Cartridges With a 15 GPM Flow Rate

UF-15 Double

1 Ultra Filtration Membrane + 2 Cartridges With A 15  GPM Flow Rate

UF-30 Quad

2 Ultra Filtration Membranes + 4 Cartridges With A 30 GPM Flow Rate

UF-60 Octuple

4 Ultra Filtration Membranes + 8 Cartridges With A 60 GPM Flow Rate

Maintenance Points

🔧 Keep your system running smoothly with these key steps:

🔹 Flush as needed – Press FL button if flow drops.
🔹 Replace membranes – If flushing doesn’t restore flow.
🔹 Monitor pressure – Keep below 45 psi; flush if high.
🔹 Sanitize (6-12 months) – Use chlorine solution, flush well.
🔹 Check for leaks (monthly) – Inspect & replace O-rings.
🔹 Inspect valves (quarterly) – Ensure proper sealing.

🔵 Use cold water | 🔵 Flush after filter changes | 🔵 Protect from freezing

BFD- High Flow Cartridges

BFD-Single

1 cartridge, Up to 7.5 GPM flow rate

Two tall white water filtration tanks mounted on a black frame with gauges and blue clamps at the top, forming a dual-tank filtration system.
BFD-Dual

2 cartridge, Up to 15 GPM flow rate

Four vertical white water filter housings connected to a dark manifold with pressure gauges at each end on a white background.
BFD-Quad

4 cartridge, Up to 30 GPM flow rate

Row of vertical water filtration cartridges connected to a manifold with pressure gauges at the top edge, for purification.
BFD-Octuple

8 cartridge, Up to 60 GPM flow rate

BFD-Single

1 cartridge, Up to 7.5 GPM flow rate

BFD-Dual

2 cartridges, Up to 15 GPM flow rate

BFD-Quad

4 cartridges, Up to 30 GPM flow rate

BFD-Octuple

8 cartridges, Up to 60 GPM flow rate

Maintenance Guide

🔹 Replace cartridge – When flow drops; twist left to remove, right to install.
🔹 Flush system – Run water 5 min after replacement.
🔹 Check for leaks – Inspect O-rings monthly, replace if worn.
🔹 Monitor pressure – Keep 20-125 psi, check gauge if at 0 psi.
🔹 Inspect rinse valve – Ensure it fully closes every 3 months.
🔹 Sanitize (6-12 months) – Use chlorine solution, flush well.

🚰 Simple steps = Reliable, clean water! 💧

Drinking Water System

Essence Pro-7

 Engineered with innovation in mind, our system boasts several advantages that set it apart from the competition, ensuring you enjoy the purest, healthiest water possible.

LED UV

These filters work by exposing water to a UV lamp, which emits high-frequency ultraviolet light that damages the DNA of microorganisms, preventing them from reproducing and rendering them harmless

Essence Pro-7

 Engineered with innovation in mind, our system boasts several advantages that set it apart from the competition, ensuring you enjoy the purest, healthiest water possible.

LED UV

These filters work by exposing water to a UV lamp, which emits high-frequency ultraviolet light that damages the DNA of microorganisms, preventing them from reproducing and rendering them harmless

Maintenance Guide

🔹 Replace Cartridges – When water flow decreases; twist left to remove, right to install​.
🔹 Flush System – Run water for 5 minutes after cartridge replacement​.
🔹 Check for Leaks – Inspect O-rings monthly; replace if worn​.
🔹 Monitor Pressure – Maintain 20-125 psi; check the gauge if pressure drops to 0 psi​.
🔹 Inspect UV LED – Ensure the LED module functions properly; replace annually for maximum disinfection​.
🔹 Sanitize System – Use chlorine solution every 6-12 months; flush thoroughly after sanitizing​​.
🔹 Check Electrical Safety – Always unplug the UV LED before maintenance; ensure GFCI protection​.

🚰 Simple Steps = Purer, Safer Drinking Water! 💧

Double Tank Water Softener & Conditioner

Two black water softener units with digital control heads; a hose connects the left unit to the others, front view with a 'Water Service' logo on tanks
TC_09

Peak flow rate up to 15 gpm
Hardness removal
Chlorines, Chloramine removal

Three tall black water filtration tanks with digital control heads, connected by a hose on the left.
TC_10

Peak flow rate up to 15 gpm
Hardness removal
Chlorines, Chloramine removal

Two tall black water treatment tanks with digital control heads and a connected line, branded Water Service Elite store/brand visible on the tanks.
TC_13

Peak flow rate up to 22 gpm
Hardness removal
Chlorines, Chloramine removal

Two tall black water filtration tanks with digital control heads on top, part of a water treatment system, branded Water Service with blue logo on the tanks.
TC_16

Peak flow rate up to 60 gpm
Hardness removal
Chlorines, Chloramine removal

Industrial water softening system: two tall black tanks with digital controllers and a brine tank in front.
TC_18

Peak flow rate up to 70 gpm
Hardness removal
Chlorines, Chloramine removal

TC_2948

Peak flow rate up to 15 gpm
Hardness removal
Chlorines, Chloramine removal 

 

 

TC_21054

Peak flow rate up to 15 gpm
Hardness removal
Chlorines, Chloramine removal

TC_21354

Peak flow rate up to 22 gpm
Hardness removal
Chlorines, Chloramine removal

TC_21665

Peak flow rate up to 60 gpm
Hardness removal
Chlorines, Chloramine removal

TC_21865

Peak flow rate up to 70 gpm
Hardness removal
Chlorines, Chloramine removal

Maintenance Guide

🔹 Replace Salt – Check salt levels monthly; add salt when below halfway.
🔹 Flush Brine Tank – Clean the tank annually to prevent salt bridging.
🔹 Inspect Resin Tank – Monitor resin beads every 2-3 years; replace if water softening declines.
🔹 Clean Injector and Venturi – Every 6 months, remove and clean to maintain water flow.
🔹 Check for Leaks – Inspect hoses and connections monthly; tighten or replace as needed.
🔹 Monitor Water Pressure – Maintain 20-100 psi; install a pressure regulator if above 80 psi​.
🔹 Sanitize System – Use chlorine solution every 6-12 months; flush thoroughly after sanitizing​.

💧 Simple Steps = Reliable, Soft Water! 💧